12V Batteries 12V 120ah Lead Battery

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union
OEM/ODM Availability
Yes
  • 12V Batteries 12V 120ah Lead Battery
  • 12V Batteries 12V 120ah Lead Battery
Find Similar Products

Basic Info.

Model NO.
SR120-12
Discharge Rate
Low Discharge Rate
Shape
Rectangle
Rechargeable
Chargeable
Size
407*174*209mm
Weight
36.50kg
Color
Black
Cell
6
Plate
Flat Plate
Separator
AGM
Battery Case
ABS
Sealing
Glue Sealing
Safety
Explosion-Proof
Terminal Type
Lead
Transport Package
Carton/ Wooden Case/ Pallet
Specification
CE/ UL
Trademark
Storace
Origin
China
HS Code
8507200000
Production Capacity
600PCS/Day

Product Description

12V Batteries 12V 120ah lead battery
(SR120-12)

Valve regulated lead acid series UPS batteries are designed with AGM (Absorbent Glass Mat) technology, high performance plates and electrolyte to gain extra power output for common power backup system applications widely used in the field of UPS, Emergency Lighting System.

Battery Structure
1. Container/Cover: Made of UL94HB and LU 94V-0 ABS Plastic
2. Negative Plates: Use the special PbCa alloy grids, optimize the recombination efficiency and less gassing.
3. Separator: Import high quality AGM separator.
4. Postive Plates: PbCa grids minimize corrosion and prolong life.
5. Terminal post: Cooper material with maximum conductivity, enhance the high current rapidly.
6. Vent Valve: Allows the release of excess gas automatically for safety.

Application
UPS, solar systems, control systems, power systems, wind energy systems, telecommunication/communication systems & etc.

Characteristics
1. Excellent safety performance
2. Good dischargeing performance
3. Good stock-proof performance
4. Good impact-proof performance
5. Good resistance to overdischarge
6. Good resistance to overcharge
7. Good resistance to high current:

Operation and maintenance manual
For maintenance free battery, it's free maintenance in the operation. But we can only use it in proper operation to keep the long lifetime of the battery,

(1) Battery Installation
Batteries should be installed possibly in a clean, cool, ventilated and dry place. The battery should be placed upright. Each terminal between the batteries is connected firmly.
(2) The ambient temperature
Ambient temperature is important factor for the battery operation. When the ambient temperature is too high, Battery plate corrosion will be increased, while absorbing more moisture; When the ambient temperature is too low, the battery will not be full charged. All this will affect the battery life. Therefore we suggest the working ambient temperature is around 25 º C.
(3) The charge and discharge current
Battery charge and discharge current usually uses the concept C, the actual value of C is related to the capacity of the battery. For example, a 100AH battery: 1C = 100A. Charging current is around 0.1C; The charging current must not be bigger than 0.3C. Discharge current general requirements in 0.05 ~ 3C range.
(4) Charging voltage
After the battery is full converted to float charging, the float voltage is around 13.0V. If the charging voltage is too high will cause the battery overcharge, otherwise the battery will not be full charged. Charging voltage is abnormal, it may be caused by the battery configuration error, or it may be caused by controller failure. Do not choose the controller with bad quality.
(5) The depth of discharge
Depth of discharge of the battery life is also a important factor for lifetime of battery, the deeper the battery discharge, the fewer the number of cycles, so battery should avoided from deep discharge.
(6) Regular maintenance
Battery should be regular checked in every period time after used, such as check its outlook, measuring the average voltage of each battery, etc.
Capacity                                                                    77° F(25º C) 20 hours rate(6.4A 10.8V) 128Ah
10 hours rate(12A 10.8V) 120Ah
5 hours rate(20.1A 10.5V) 100.5Ah
1 hour rate(87A 9.6V) 87Ah
Internal Resistance Full charged battery 77° F(25º C): 4.2mΩ
Capacity affected by Temperature                              (10 hour rate) 104° F(40º C) 102%
77° F(25º C) 100%
32° F(10º C) 85%
5° F(-15º C) 65%
Self-Discharge                        68° F(20º C) Capacity after 3 month storage 90%
Capacity after 6 month storage 80%
Capacity after 12 month storage 60%
Max discharge current77° F(25º C): 950A(5S)
Charge                                                    (Constant Voltage) Float: 13.6 to 13.8V/77° F/(25º C)
Cycle: 14.4 to 14.7V/77° F/(25º C)
Max Current: 30A

12V Batteries 12V 120ah Lead Battery
12V Batteries 12V 120ah Lead Battery
12V Batteries 12V 120ah Lead Battery
12V Batteries 12V 120ah Lead Battery
12V Batteries 12V 120ah Lead Battery
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier