Customization: | Available |
---|---|
Nominal Voltage: | 51.2V |
Warranty: | 3 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Project | Parameters | ||||
Model | 51.2V50Ah | 51.2V100Ah | 51.2V150Ah | 51.2V200Ah | 51.2V300Ah |
Nominal voltage | 51.2V | ||||
Nominal capacity | 50Ah (2560wh) | 100Ah (5120wh) | 150Ah (7680wh) | 200Ah (10240wh) | 300Ah (15360wh) |
Dimensions (mm) | 500*360*120 | 570*360*140/ 600*420*210 |
860*540*160 | 860*620*200 | |
Weight | About 30KG | About 53KG | About 80KG | About 90KG | About 120KG |
Working voltage | 45---58.4V | ||||
Floating charge voltage | 54.4---55.2V | ||||
Equalizing charge voltage | 56---58.4V | ||||
Charging current limiting | 10A(The default charging current is greater than 55A, and the current limiting is on) It can be set through the upper computer | ||||
Standard charging current current | 10A | 20A | 30A | 40A | 40A |
Maximum continuous charging current | 25A | 40A | 50A | 50A | 50A |
Standard discharge current | 17A | 33A | 50A | 66A | 80A |
Maximum continuous discharge current | 50A | 100A | 100A | 100A | 100A |
Charging ambient temperature | 0~50 ºC | ||||
Discharge ambient temperature | -20~60ºC | ||||
Storage ambient temperature | 0~60ºC | ||||
Working environment | Humidity :≤95; Altitude :≤4000 | ||||
Communication mode | It has the following communication ports CAN, RS485-1, RS232, RS485-2; CAN and RS485-1 are responsible for communicating with the inverter; RS232 is responsible for the communication with BMS upper computer, and is used as the battery software upgrade interface at the same time; RS485-2 is responsible for parallel communication between batteries. | ||||
Power display mode | LED light / display |
Nominal Voltage | 51.2V | |
Nominal Capacity | 100Ah | |
Energy | 5.12KWh | |
Combination mode | 16S1P | |
Cycle Life | ≥6000 Cycle, 80%DOD, 25ºC | |
BMS configuration | 16S100A | |
Operating voltage range | 41.6V~59.2V | |
Rated charge and discharge current | 50A | |
Peak current | 100A Continue @120A 3s | |
Rated charging and discharging power | 2.56Kw | |
Peak power | 5.12Kw Continue @6.144Kw 3s | |
Short-circuit current | 0.377Ka@100us | |
Communication mode | CAN, RS485 | |
Parallel number | Recommend 6 in parallel(Maximum support 16 in parallel) | |
Remote data | Bluetooth optional/Wifi | |
Weight | 120kg | |
Dimensions (L*W*H) mm | 720*260*580mm | |
Operating temperature | Charging: 0ºC~+50ºC / Discharge: -10ºC~+60ºC | |
Relative humidity | 0~95% | |
Storage temperature | <3 Months -10ºC~25ºC / <1 Year 0ºC~25ºC | |
Maximum working altitude | 2000m | |
Class of protection | IP21 | |
Supports inverter communication brands | SMA/Growatt/TBB/Deye/GOODWE/Huawei/Victon energy/SOFAR/INVT | |
Installation mode | Wall mounting | |
Power cable outlet mode | upper | |
Standards and certification | Transport UN38.3 | |
Note | Rated charge and discharge current and power will change due to temperature and SOC. |
1.Environmental protection and pollution-free: the whole module using materials are non-toxic, pollution-free;
2.long safety life: the core cathode material of battery module is made of LiFeOP4, good safety performance and long service life;8.Wide temperature range: working temperature range-20~70, charge 0~60, discharge-20~70, good discharge performance and cycle life,
Built in BMS overall protection
1.Over charged protection
2.Over discharged protection
3.Thermal protection
4.Over current protection
5.Cell balancing
Interface definition and description
1 | Reset switch | 7 | RS232 |
2 | Dry contact | 8 | RS485-2(Parallel communication port) |
3 | Indicator light | 9 | Output positive |
4 | Address dialing | 10 | Output negative pole |
5 | RS485-1(Inverter communication port) | 11 | LCD |
6 | CAN |
Q1. Can I have a sample order?