Guangdong, China
Business Type:
Manufacturer/Factory & Trading Company
Business Range:
Electrical & Electronics, Industrial Equipment & Components
Year of Establishment:
2008-01-22
Terms of Payment:
LC, T/T, Western Union
OEM/ODM Availability:
Yes
OEM/ODM Service
Sample Available

Lead Acid Battery, Sealed Lead Acid Battery, Agm Battery manufacturer / supplier in China, offering 12V AGM Batteries, 12V 75ah Sealed Lead Acid Battery (SR75-12), Deep Cycle Battery 12V 100ah SLA Battery, Gel Battery, SRG33-12 12V33ah SMF Colloid Battery 12V 33ah and so on.

Gold Member Since 2012
Audited Supplier
Supplier Homepage Products All kinds of batteries ups battery 12V AGM Batteries, 12V 75ah Sealed Lead Acid Battery (SR75-12)

12V AGM Batteries, 12V 75ah Sealed Lead Acid Battery (SR75-12)

Get Latest Price
Min. Order / Reference FOB Price
40 Pieces US $69-105/ Piece
Production Capacity: 2000PCS Each Day
Transport Package: Carton/ Wooden Case/ Pallet
Payment Terms: L/C, T/T, Western Union
Type: Lead-Acid Batteries
Usage: UPS, Lighting
Nominal Voltage: 12V
Discharge Rate: Low Discharge Rate
Shape: Rectangle
Rechargeable: Chargeable

You Might Also Like

Loading...

Basic Info

Model NO.: SR75-12
Size: 260*169*215 Mm
Color: Black / Dark Gray
Cell: 6
Separator: AGM
Plate: Flat Plate
Sealing: Glue Sealing
Terminal Type: Copper
Battery Case: ABS
Safety: Explosion-Proof
Accessory: Screws
Trademark: STORACE
Specification: CE/ UL
Origin: Guangzhou, China
HS Code: 8507200000

Product Description

12v AGM Batteries, 12v 75ah sealed lead acid battery(SR75-12)
(SR75-12 )

Valve regulated lead acid series UPS batteries are designed with AGM (Absorbent Glass Mat) technology, high performance plates and electrolyte to gain extra power output for common power backup system applications.

Battery Structure
1. Container/Cover: Made of UL94HB and LU 94V-0 ABS Plastic
2. Negative Plates: Use the special PbCa alloy grids, optimize the recombination efficiency and less gassing.
3. Separator: Import high quality AGM separator.
4. Positive Plates: PbCa grids minimize corrosion and prolong life.
5. Terminal post: Cooper material with maximum conductivity, enhance the high current rapidly.
6. Vent Valve: Allows the release of excess gas automatically for safety.

Application
Control systems, Electric toys, Emergency lamp, Power tools, Medical treatment equipment, Alarm system, Emergency light system, Standby power supply, UPS and computer standby power supply, Power system, Telecommunication system, Firefighting equipment standby power supply, Railway station, Ship Equipment, Military Equipment, Telephone switching system.


Characteristics
· Excellent safety performance.
· Good discharging performance.
· Good stock-proof performance.
· Good impact-proof performance.
· Good resistance to over discharge.
· Good resistance to overcharge.
· Good resistance to high current.

Operation and maintenance manual
For maintenance free battery, it's free maintenance in the operation. But we can only use it in proper operation to keep the long lifetime of the battery,

(1) Battery Installation
Batteries should be installed possibly in a clean, cool, ventilated and dry place. The battery should be placed upright. Each terminal between the batteries is connected firmly.
(2) The ambient temperature
Ambient temperature is important factor for the battery operation. When the ambient temperature is too high, Battery plate corrosion will be increased, while absorbing more moisture; When the ambient temperature is too low, the battery will not be full charged. All this will affect the battery life. Therefore we suggest the working ambient temperature is around 25 º C.
(3) The charge and discharge current
Battery charge and discharge current usually uses the concept C, the actual value of C is related to the capacity of the battery. For example, a 100AH battery: 1C = 100A. Charging current is around 0.1C; The charging current must not be bigger than 0.3C. Discharge current general requirements in 0.05 ~ 3C range.
(4) Charging voltage
After the battery is full converted to float charging, the float voltage is around 13.0V. If the charging voltage is too high will cause the battery overcharge, otherwise the battery will not be full charged. Charging voltage is abnormal, it may be caused by the battery configuration error, or it may be caused by controller failure. Do not choose the controller with bad quality.
(5) The depth of discharge
Depth of discharge of the battery life is also a important factor for lifetime of battery, the deeper the battery discharge, the fewer the number of cycles, so battery should avoided from deep discharge.
(6) Regular maintenance
Battery should be regular checked in every period time after used, such as check its outlook, measuring the average voltage of each battery, etc.
Capacity                                   77°F(25ºC) 20 hours rate(3.85A 10.8V) 77Ah
10 hours rate(7.5A 10.8V) 75Ah
5 hours rate(13.5A 10.5V) 67.5Ah
1 hour rate(48.5A 9.6V) 48.5Ah
Internal Resistance Full charged battery 77°F(25ºC):8mΩ
Capacity affected by Temperature                (10 hour rate) 104°F(40ºC) 102%
77°F(25ºC) 100%
32°F(10ºC) 85%
5°F(-15ºC) 65%
Self-Discharge             68°F(20ºC) Capacity after 3 month storage 90%
Capacity after 6 month storage 80%
Capacity after 12 month storage 60%
Max discharge current77°F(25ºC):700A(5S)
Charge                           (Constant Voltage) Float:13.6 to 13.8V/77°F/(25ºC)
Cycle:14.5 to 14.9V/77°F/(25ºC)
Max Current:18.8A